Page 189 - Radar ve Arpa Radar Siber Kitap
P. 189
6. Collision warning CPA limit: 0.2 - 10 nm, TCPA limit: 0 - 99
min.
7. Trial maneuver Dynamic or static, with selected delay time.
AIS Display (Data input from AIS is required)
1. Symbols Sleeping, Activated, Dangerous, Selected, Lost
targets
2. Number of targets 1,000 targets max.
3. Data indication Basic and expanded data
Power Supply
1. Processor Unit
24 VDC or 115/230 VAC, 1ø, 50/60 Hz,
7.6 A (FAR-2117: 24 rpm at 24 VDC),
8.8 A (FAR-2127: 24 rpm at 24 VDC)
440 VAC, 1ø, 50/60 Hz with optional transformer RU-1803
2. Display Unit
24 VDC or 115/230 VAC, 1ø, 50/60 Hz, 2.3 A (24 VDC)
440 VAC, 1ø, 50/60 Hz with optional transformer RU-1803
3. Antenna Unit
FAR-2137S:
230 VAC, 3ø, 60 Hz; 380 VAC, 3ø, 50 Hz; 440 VAC, 3ø, 60 Hz
© 2018 Digital Galaxy Back to Index 189